Brazed Plate Heat Exchangers

Brazed Plate heat Exchangers from SonFlow
Brazed heat exchangers various models

 

 

Permanently Sealed
Brazed Heat Exchangers

SonFlow’s efficient brazed heat exchangers (SFB) are permanently sealed heat exchangers suitable for a wide variety of applications across numerous market segments.

For the brazed heat exchanger series, the key focus lies in reliability and high performance. Our talented team with more than 45 years of experience in heat exchangers has developed and thoroughly tested the efficient brazed heat exchangers, handling advanced heat transfer technology.

 

Features

Every detail is carefully designed to ensure optimal performance, reduce maintenance costs, and decrease downtime.
One of our focus areas is sustainability and therefore it is important that the units are energy-efficient and environmentally friendly.

   

    Advantages of SonFlow Brazed Heat Exchangers

 

  • High Configuration Flexibility
  • Compact Size
  • Copper Brazed Construction
    Gasket free
  • Close Approach Temperature
    Possible to achieve close approach temperatures
  • Easy and Quick Installation
  • Less Fouling
    A smooth plate surface minimizes fouling
  • Lower Costs
  • Maintenance and Service Friendly

 

 

Brazed heat exchanger connection

Construction

The Brazed heat exchanger is constructed by a package of thin corrugated metal plates, surrounded by two thicker stabilizing plates. A thin copper foil placed between each of the thin metal plates melts and seals the brazed plate heat exchanger during a vacuum brazing process.

 

We calculate each solution based on the customer’s requirements to ensure an ideal pressure drop and flow rate. And at the same time, the unit becomes energy-efficient and environmentally friendly. Based on the individual task, we also determine the number of plates and the size of the brazed heat exchangers.

 

Construction of a brazed heat exchanger

 

 

 

1: At the inlet, the medium enters the heat exchanger and is evenly distributed across the plates, ensuring optimal flow and heat transfer efficiency.

 

2: The two media flow in separate channels, divided by the plates. This ensures efficient heat transfer without any risk of mixing.

Plates

The design of the corrugated plates optimizes heat transfer by providing a large but compact total surface area whereby the heat can be drawn from one liquid or gas to another.
The plates are optimised to meet specific temperature demands and capacities.

 

Designed to meet your needs

Our extensive range ensures that we can offer the best solution at the best price and, if required, combine several different types of heat exchangers to ensure that you get the best possible solution.

 


 

We are ready to assist you

No matter what challenge you are facing, we are always ready to advise you on the best solution for pumps and plate heat exchangers.

Plate Heat Exchangers:
+45 86 57 13 44
info@sonflow.dk


See further contact information here.

 


 

Industries:

The compact brazed heat exchangers can be used in nearly all areas of heating and cooling processes, including:

  • General cooling/heating
  • HVAC
  • Refrigeration
  • Industrial
  • Marine
  • Data centres
  • Heat pump
  • Solar heating

Brazed Heat Exchanger Benefits:

  • Lower operating and life cycle costs
  • High thermal transfer efficiency
  • Increased energy savings
  • Lightweight and easy to handle
  • Robust, solid construction
  • Extremely small footprint
  • Minimal service and maintenance
  • Solid construction

 


 

Brazed Heat Exchangers Productline

Brazed productline
  A B C D E L1 Max N
SFB18 TL 320 mm 95 mm 270 mm 45 mm 28 mm (N x 1.3) +8 mm 101
SFB18 TXL 320 mm 95 mm 270 mm 45 mm 28 mm (N x 1.3) +8 mm 101
SFB19 TK 329 mm 93 mm 279 mm 43 mm 28 mm (N x 2.3) +8 mm 101
SFB21 TL 291 mm 114 mm 242 mm 65 mm 28 mm (N x 1.9) +9 mm 101
SFB22 TL 495 mm 114 mm 446 mm 65 mm 28 mm (N x 1.9) +9 mm 101
SFB25 TL 526 mm 119 mm 479 mm 72 mm 28 mm (N x 2.3) +8 mm 101
SFB25 TM 526 mm 119 mm 479 mm 72 mm 28 mm (N x 2.3) +8 mm 101
SFB25 TK 526 mm 119 mm 479 mm 72 mm 28 mm (N x 2.3) +8 mm 101
SFB31 TL 305 mm 128 mm 242 mm 65 mm 28 mm (N x 2.1) +9 mm 101
SFB32 TL 509 mm 128 mm 446 mm 65 mm 28 mm (N x 2.1) +9 mm 151
SFB32 TM 509 mm 128 mm 446 mm 65 mm 28 mm (N x 2.1) +9 mm 151
SFB32 TK 509 mm 128 mm 446 mm 65 mm 28 mm (N x 2.1) +9 mm 151
SFB51 TL 618 mm 191 mm 519 mm 92 mm 30 mm (N x 2.3) +11 mm 201
SFB51 TM 618 mm 191 mm 519 mm 92 mm 30 mm (N x 2.3) +11 mm 201
SFB51 TK 618 mm 191 mm 519 mm 92 mm 30 mm (N x 2.3) +11 mm 201
SFB61 TL 617 mm 247 mm 520 mm 150 mm 40 mm (N x 2.5) +9.5 mm 201
SFB61 TXL 617 mm 247 mm 520 mm 150 mm 40 mm (N x 2.5) +9.5 mm 201
SFB61 TM 617 mm 247 mm 520 mm 150 mm 40 mm (N x 2.5) +9.5 mm 201
SFB61 TK 617 mm 247 mm 520 mm 150 mm 40 mm (N x 2.5) +9.5 mm 201
SFB81 TL 748 mm 330 mm 623 mm 205 mm   (N x 2.3) +12 mm 271
SFB81 TM 748 mm 330 mm 623 mm 205 mm   (N x 2.3) +12 mm 271
SFB81 TK 748 mm 330 mm 623 mm 205 mm   (N x 2.3) +12 mm 271
SFB101 TL 1004 mm 381 mm 862 mm 239 mm   (N x 2.4) +10 mm 271
SFB101 TM 1004 mm 381 mm 862 mm 239 mm   (N x 2.4) +10 mm 271
SFB101 TK 1004 mm 381 mm 862 mm 239 mm   (N x 2.4) +10 mm 271

 

Measurements are in mm
N = Number of plates

Measurement of a brazed heat exchanger from SonFlow

Specifications

Cleaning and maintenance

All our plate heat exchangers are designed with a focus on providing easy access for quick and hassle-free inspection, maintenance and cleaning.

  • The plates in our brazed plate heat exchangers are made from stainless steel, ensuring they are easy to clean.
  • The heat exchanger supports CIP-cleaning (Cleaning in Place), allowing it to be cleaned directly within the system without requiring disassembly or relocation. This feature simplifies post-use cleaning, ensuring that your system remains free from contamination in the next production cycle.

Find our guide for CIP-Cleaning our Brazed Heat Exchanger here.

Flange Connections

Our brazed plate heat exchangers SFB81 and SFB101 can be supplied with robust flange connections for secure and reliable integration into your piping system.

  • Flanges provide a strong mechanical joint, making them ideal for applications with higher pressures, larger pipe diameters, or systems requiring frequent disassembly for maintenance.
  • Manufactured from high-quality, corrosion-resistant materials, the flanges ensure a long service life and leak-free performance.

Insulation Jackets

SonFlow brazed plate heat exchangers can be delivered with insulation jackets to reduce energy consumption and prevent condensation and ice formation.

  • Thermal insulation jackets reduce energy waste by preventing excessive heat and cold loss. The jackets also create a safer working environment by protecting against burns and scalds.
  • The insulation jackets are available in high-quality glass wool or polyurethane foam, encased by an aluminium plate.
  • The jackets are manufactured in sections joined together with spring locks, ensuring a smooth installation and an effective assembly/disassembly process for easy maintenance.

Specifications

  SFB18 SFB19 SFB21 SFB22 SFB25 SFB31 SFB32 SFB51 SFB61 SFB81 SFB101
MATERIALS                      
Plate material: AISI 316 X X X X X X X X X X X
Brazing material: Copper X X X X X X X X X X X
MAX DESIGN PRESSURE                      
16 bar (232 PSI)               X X X X
25 bar (362 PSI) X X X X X X X X X X X
40 bar (580 PSI)           X X X X    
TEMPERATURE                      
-100 to 185˚C (-148 til 365˚F) X X X X X X X X X X X
CONSTRUCTION STANDARDS                      
EN13445 (PED 2014/68/EU)
X X X X X X X X X X X
ASME Section VIII, Div. 1 X X X X X X X X X X X
CONNECTIONS                      
¾” inside pipe thread ISO 7-R
X X X X X            
¾” outside pipe thread ISO 7-R X X       X X        
1” Pipe Thread ISO 7-R X X X X X X X        
1 ¼” Pipe Thread ISO 7-R           X X        
1 ½” Pipe Thread ISO 7-R           X X        
2” Pipe Thread ISO 7-R               X X    
2 ½” Pipe Thread ISO 7-R                 X    
Ø 22.3 - M34 x1.5           X X        
Ø 28.2 - M34 x1.5           X X        
Ø 42.2               X      
Ø 54.2 - ISO 7-R 1 ½”                 X    
Ø 70.2 - ISO 7-R 3”                 X    
DN 80 Flange SS PN16                   X  
DN 80 Flange SS PN25                   X  
DN 100 Flange SS PN16                     X
DN 100 Flange SS PN25                     X
3” Flange SS ANSI B16.5 #300                   X  
3” Flange SS ANSI B16.5 #150                   X  
4” Flange SS ANSI B16.5 #150                     X
4” Flange SS ANSI B16.5 #300                     X
NPT threads upon request X X X X X X X X X    
ACCESSORIES                      
Insulation jackets
X X X X X X X X X X X
Foundation feet X X X X X X X X X X X
Mounting brackets X X X X X X X X      

 

 

Product Overview - Brazed Plate Heat Exchangers

plate heat exchanger SF10 series

Brazed plate heat exchanger SFB20

plate heat exchanger SF25 series

Brazed plate heat exchanger SFB30

Brazed plate heat exchanger SFB50

Brazed plate heat exchanger SFB60

Brazed plate heat exchanger SFB80

Brazed plate heat exchanger SFB100


 

We are ready to assist you

No matter what challenge you are facing, we are always ready to advise you on the best solution for pumps and plate heat exchangers.

Plate Heat Exchangers:
+45 86 57 13 44
info@sonflow.dk


See further contact information here.

Contact SonFlow about brazed plate heat exchanger

Cookies